Part Number Hot Search : 
1N4963US TFR433G1 36230 FFM301 18AB7 18AB7 0E4D1 74LS42
Product Description
Full Text Search
 

To Download 0318-2 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  www.lumberg.com 05/2010 0318-2 polbilder, von der l?tseite gesehen pin configurations, solder side view schmas de raccordement, vus du c?t souder 0318-2 06-1 0318-2 08-1 swum?-flansch-einbaustecker nach iec 61076-2-106 und aisg-spezifikation, ip 68/67, mit schraubverschluss und l?t- anschlssen, fr frontmontage 1. temperaturbereich -40 c/+85 c 2. werkstoffe kontakttr?ger pa, v2 nach ul 94 kontaktstift cuzn, versilbert und flashvergoldet geh?use zn-druckguss, vernickelt dichtung nbr 3. mechanische daten kontaktierung mit kupplungen 032..., 0360 kupplungen nach iec 61076-2-106 und iec 60130-9 schutzart 1 ip 68/67 anschlussquerschnitt 0,75 mm2 4. elektrische daten (bei t u 20 c) bemessungsstrom 5 a bemessungsspannung 2 60 v ac isolierstoffgruppe 2 iiia (iec)/2 (ul) (cti 350) prfspannung 1 kv/60 s isolationswiderstand > 1 t 1 nach iec 60529/din en 60529 ip 68: dicht in verschraubtem zustand; mit einem zugeh?rigen gegen stck verschraubte steckverbindung ist gegen eindringen von staub oder feuch- tigkeit geschtzt ip 67: dicht in ungestecktem zustand (swum?); durch einen versehent- lich ungeschtzten ungesteckten steckverbinder k?nnen staub oder feuchtigkeit nicht in das ger?teinnere eindringen ip-x8-anforderungen in absprache zwischen anwender und hersteller 2 nach iec 60664/din en 60664, cti fr ul nach ansi/ul 746 a *a flachdichtung flat gasket joint dtanchit plat *b l?tkelch bell-shaped solder terminal plot souder en forme de coupe *c montagerichtung mounting direction direction de montage *d einbau?ffnung port ouverture demplacement *e geeignete schraubenabdichtung ist vorzusehen provide for suitable sealing of screws prvoir tanchement des crous appropri
www.lumberg.com 05/2010 0318-2 0318-2 swum?-rundsteckverbinder mit schraubverschluss nach iec 61076-2-106 und aisg-spezifikation, ip 68 swum? circular connectors with threaded joint acc. to iec 61076-2-106 and aisg specification, ip 68 connecteurs circulaires swum? avec verrouillage vis suivant cei 61076-2-106 et spcification aisg, ip 68 verpackung: im karton packaging: in a cardboard box emballage: dans un carton swum ? dicht im ungesteckten zustand s ealed w hen u n m ated tanche ltat non enfich bestellbezeichnung polzahl verpackungseinheit designation poles package unit dsignation p?les unit demballage 0318-2 06-1 6 50 0318-2 08-1 8 50 swum? flange chassis plug acc. to iec 61076-2-106 and aisg specification, ip 68/67, with threaded joint and solder terminals, for front mounting 1. temperature range -40 c/+85 c 2. materials body pa, v2 according to ul 94 contact pin cuzn, silvered and flash gilded housing zn diecast, nickeled gasket nbr 3. mechanical data mating with sockets 032..., 0360 sockets according to iec 61076-2-106 and iec 60130-9 protection 1 ip 68/67 wire section 0.75 mm2 4. electrical data (at t amb 20 c) rated current 5 a rated voltage 2 60 v ac material group 2 iiia (iec)/2 (ul) (cti 350) test voltage 1 kv/60 s insulation resistance > 1 t 1 according to iec 60529/din en 60529 ip 68: sealed in locked position; pair of appropriate connectors in locked position is sealed against ingress of dust and moisture ip 67: sealed when unmated (swum?); no dust or moisture can ingress into the inside of the device through an unmated connector accidential- ly left unprotected ip x8 requirements under agreement between user and manufacturer 2 according to iec 60664/din en 60664, cti for ul acc. to ansi/ul 746 a embase male swum? collerette suivant cei 61076-2-106 et spcification aisg, ip 68/67, avec verrouillage vis et connexion par soudurepour montage de front 1. temprature dutilisation -40 c/+85 c 2. matriaux corps isolant pa, v2 suivant ul 94 contact broche cuzn, argent et dor flash bo?tier zn moul sous pression, nickel joint dtanchit nbr 3. caractristiques mcaniques raccordement avec connecteurs femelles 032..., 0360 connecteurs femelles suivant cei 61076-2-106 et cei 60130-9 protection 1 ip 68/67 section de raccordement de fil 0,75 mm2 4. caractristiques lectriques ( t amb 20 c) courant assign 5 a tension assigne 2 60 v ac groupe de matriau 2 iiia (cei)/2 (ul) (cti 350) tension dssai 1 kv/60 s rsistance disolement > 1 t 1 suivant cei 60529/din en 60529 ip 68: tanche ltat verrouill; un pair de connecteurs approppris ltat verrouill est protg contre la poussire et lhumidit ip 67: tanche ltat non enfich (swum?); ni poussire ni humidit ne peuvent entrer dans lappareil au travers dun connecteur non enfich et non protg par ngligence exigences ip x8 aprs entente entre utilisateur et fabricant 2 suivant cei 60664/din en 60664, cti pour ul suivant ansi/ul 746 a


▲Up To Search▲   

 
Price & Availability of 0318-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X